Good Quality Forced Spirometry - FVC, FEV1
This video demonstrates a standardized forced spirometry maneuver, highlighting effective patient preparation and coaching by the technician, followed by good quality performance by the participant and a brief review of the flow/volume graph and the the volume/time graph. The example aligns with the fundamental requirements of the ATS/ERS 2019 guidelines for good quality spirometry testing.
MasterScope Setup: Unboxing and Connecting ECG & WSSU
Take a look at the MasterScope setup. This includes checking the ECG device, connecting the cables, and setting up the Wireless Spirometry Sensor Unit (WSSU).
Diffusion Capacity of the Lung - DLCO
While collecting data during a respiratory clinical trial, site staff must ensure that lung diffusion testing is conducted correctly. View this video to learn the simple steps for measuring your patient’s DLCO (diffusing capacity of the lung for carbon monoxide).
MasterScope - How to log into Subject Mode with Subject Mode Activation PIN
If your site is using Clario’s MasterScope device to gather respiratory data during a clinical trial, you must use a Subject Mode Activation PIN to log into Subject Mode. This PIN is received after passing the Proficiency Test.
View this video to learn how to access your Subject Mode Activation PIN and log into Subject Mode on the MasterScope.
VC Measurement: Effective Patient Coaching
This video demonstrates a standardized Slow Vital Capacity (SVC) measurement, highlighting effective participant preparation and clear coaching by the investigator. It shows proper technique and steady, controlled breathing from the participant, in alignment with the core principles of the ATS/ERS guidelines for high-quality VC measurements.
Uploading DLCO Documentation into the Clario Portal
This tutorial demonstrates the workflow for uploading DLCO reports to the Clario Portal for centralized data review via the Data Entry function. This video covers preparing the required files, completing the submission in the Clario Portal, and answering follow-up queries.
NDD Easy One Pro Setup
In this video, we show you the step-by-step instructions for setting up the Easy One Pro device.
Gas Handling for the NDD EasyOne Pro
This video provides a step-by-step overview of how to correctly set up a DLCO test gas cylinder with a pressure regulator and connect it to the EasyOne Pro device. It guides you through the installation process, highlights key considerations to ensure a secure and proper connection, and demonstrates how to adjust the regulator to the required operating pressure for reliable testing.
Home Coached Spirometry
This video guides you on how to perform a virtual visit using the iSpiro Ultrasonic Sensor Solution.
Calibration Check for the NDD EasyOne Pro Device
This is a short demonstration of the calibration check procedure for NDD EOP device.